SWAS Equipment

SAMPLE COOLERS. SC

Cooling the sample before analysis

The coolers´ SC series provide high cooling efficiency, being most suitable for most liquid, gas, or steam process applications.

Data Sheet

RESIN COLUMN. CR

For measurement of cationic conductivity

The function of the cationic resin columns is the removal by exchange of all the cations contained in a sample that come mainly from the dosage of some compound. The most commonly removed cations are the NH4 + from the amine dosage.

Data Sheet

DEGASSER. DG-50

For degassed conductivity measurement

The degassed DG-50, is a device designed to degas the sample to be analyzed in water-steam cycles, eliminating dissolved gases, especially CO2 and obtaining a measurement of degassed conductivity.

This design occupies minimum space and allows the integration of degassed, degassed + cationic or degassed + cationic + specific measurements in the degassed itself.

Data Sheet

DEGASSER. DG-105

With temperature adjustment @ Atmospheric pressure

The degassed DG-105, is a device designed to degas the sample to be analyzed in water-steam cycles, eliminating dissolved gases, especially CO2 and obtaining a measurement of degassed conductivity.

The advanced design of the DG-105 temperature degasser, performs an automatic temperature setpoint according to the atmospheric pressure , thus rapidly obtaining  the degassed conductivity measurement, since it is not required to reach boiling point.

Data Sheet

BACK PRESSUER RELIEF VALVE. BPR

To stabilize pressure and flow in the sample before analysis / Safety valve

The pressure regulating valve BPR is used in lines of sampling systems, before the input to the analyzers, providing a constant pressure and flow of input to the analyzers.

Data Sheet

THERMAL SHUT-OFF VALVE. TVS

For protection of people and analyzers in cases of high temperatures

In the event that the sample temperature rises above the operating temperature of 49 ° C (120 ° F), the VTS thermal actuator modulates the valve to close the inlet port and prevent damage to equipment and instrumentation.

Data Sheet

PRESSURE REDUCED VALVE “Rod-in-tube”. HPRV

To reduce high pressures avoiding jams due to dirt in the line

The HPRV high pressure reducing valve is designed for high pressure lines in sample systems, with an inlet pressure between 35 and 350 barg.

Its design is specific to be used in conjunction with the BPR

Data Sheet

STREAMS SEQUENCER. SQ

To obtain measurements of up to eight samples, with only one or two analyzers

System to measure several samples through a single analyzer, differentiating the measurement of each sample with independent outputs. Our sequencers can operate two analyzers at once and up to eight different samples.

The manifold block is directly coupled to the sequencer, which saves space and avoids inter-wiring between the sequencer and solenoid valves.

Data Sheet

WATER CHILLER. WTCU

To stabilize the sample temperature at the ideal analysis temperature

The temperature control unit (WTCU) is a water condenser cooling system, which is responsible for providing the appropriate temperature to the cooling water that is used as a cooling fluid in the secondary coolers of the sample lines, in order to obtain a stable temperature of it.

Data Sheet

CONDITIONING PANELS. CP

Panels for sample conditioning.

These panels are delivered fully integrated with the components selected by our clients. Built according to ASME PTC 19.11 standard, they allow multiple configurations according to customer needs.

They allow attaching another panel with analyzers to have a conditioning and analysis system for a sample in a single panel.